How do you compare solar offers?

Holding two or three offers for your site's plant? This guide puts them on the same basis and tells you what to ask each company before you choose.

By the engineering team at pv.directLast updated: 21 November 2026

Before you compare: the same basis.

Two offers built on different bases cannot be compared by price. First make sure every offer is built on:

  • The same roof and the same available area.
  • The same consumption: send every company the same bills.
  • The same panel capacity in kilowatt-peak (kWp). If the capacities differ, ask each company for an offer at the same capacity.
  • And with it, the inverter's capacity in kilowatts of alternating current (AC).

The inverter's capacity is the most the plant can deliver to your site at any one moment, and it is normal for the panels' capacity to be slightly higher. What matters is that you have both figures in writing.

The capacity in any offer is preliminary until the distribution company reviews the technical file; the approved capacity may differ.

Six fields in any offer.

Look for these six fields in every offer. A missing field is a question to ask before you compare.

123456
Illustrative drawingA generic offer; the order of the fields differs from one company to another.
  1. The plant's capacity. The panels' capacity in kilowatt-peak (kWp), with the inverter's capacity beside it.
  2. The expected yearly production. In kilowatt-hours (kWh), with the basis of the figure.
  3. The components. Panels, inverter, mounting structure, cables and protection devices, by manufacturer and model.
  4. The warranties. How long each warranty runs, and who answers for it.
  5. The scope of work. What the offer includes and what it does not, and who prepares the technical file for the grid connection.
  6. The price basis and the payment schedule. What the price covers, and which stage each payment is tied to.

Expected production: where does the figure come from?

The same capacity on the same roof produces about the same energy in a year. A small difference between offers is normal, because each design has its own tilt and its own assumptions about losses. A large difference needs an explanation.

Ask each company how many kilowatt-hours per kilowatt-peak a year its offer assumes, and whether the figure is calculated for your site and roof or is a general one. Ask, too, whether it is the first year's production, because panels produce slightly less every year. A higher figure in an offer does not mean a more suitable plant.

Capacity and production: kWp and kWh

Yearly yield per kilowatt peak in the glossary

Components: by make and model.

Ask for every component in writing, by manufacturer and model, so that you can compare item by item:

  • Panels and inverter: ask for the datasheet of each model.
  • The number of panels multiplied by each panel's rating must equal the plant's capacity. Example: 200 panels of 550 W make 110 kWp.
  • Mounting structure: its material, aluminium or galvanised steel, and how it is fixed to the roof.
  • Cables and protection devices: each item with its type and quantity, not under the word “accessories”.

The net-metering rules issued by the Egyptian Electric Utility and Consumer Protection Regulatory Agency (EgyptERA) in February 2026 require local content of no less than 25% of the project's total components. The share is calculated on the value of all the project's items, design and installation work among them, not on the equipment alone. The New and Renewable Energy Authority approves it before installation, so ask each company how its offer meets it.

Egyptian Electric Utility and Consumer Protection Regulatory Agency (EgyptERA): rules for connecting solar plants under net metering, February 2026 (in Arabic)

Warranties: who stands behind each one.

Panels carry two manufacturer warranties, each with its own terms: the product warranty against manufacturing defects, and the performance warranty, a minimum for the panel's output over the years. The inverter has a manufacturer warranty of its own. The warranty on the installation work is the installer's, and the contract sets it out.

For each warranty ask how long it runs, what it excludes, and whom you call in Egypt if something fails. The net-metering rules provide that the qualified installer gives you an approved warranty certificate for the main components, naming the guarantor or the authorised importer and the official means of reaching them; ask for it.

Ask about maintenance after the installer's warranty ends, too: the same rules oblige the owner of a plant of 100 kW AC or more to sign a maintenance contract with a company qualified by the New and Renewable Energy Authority, and the owner of a smaller plant to sign a contract for remote follow-up of its performance.

At pv.direct: equipment warranties come from the manufacturers on their terms; the installation work and maintenance are the responsibility of our Egyptian company, as the contract sets out.

Scope of work and price.

Under the net-metering rules, preparing the technical file for the grid connection and submitting it to the distribution company is the qualified installer's task. Make sure the offer says so, and ask who follows up the procedure after submission. Ask, too, whether the installer is qualified by the New and Renewable Energy Authority for your plant's capacity.

The Gold qualification

Make sure the company named on the offer is the one that will sign the contract with you.

Contract and signature

Then compare the totals for the same scope. Ask each company what its price does not include, such as:

  • Civil works, and any repair or strengthening of the roof.
  • Changes to your site's main distribution board.
  • The distribution company's fees: the study of the technical file and the measurements, and the bidirectional meter.
  • The study of the plant's impact on the grid, for a connection to the medium-voltage network.

An offer that leaves items out does not really have a lower price. Ask whether the price is final, and what could change it. Compare the payment schedule as well: which stage each payment is tied to, from supply to installation to commissioning.

If an offer shows financial projections, ask which production and which electricity prices they assume, and how they count the surplus. With net metering, the surplus is credited as energy under the distribution company's rules.

Your questions for every offer.

Ask every company the same questions, and compare the answers side by side.
ItemWhat to askWhy it matters
CapacityHow many kWp of panels, and how many kilowatts of inverter?So that you compare plants of the same size.
ProductionHow many kWh per kWp a year, and where does the figure come from?Every projection that follows rests on it.
ComponentsThe manufacturer, the model and the datasheet of each item?So that you know exactly what you will receive.
WarrantiesHow long is each warranty, what does it exclude, and whom do you call in Egypt?The manufacturer's warranty is not the installer's.
QualificationDoes the company's qualification tier cover your plant's capacity?The distribution company checks that the installer is qualified.
Connection fileAre preparing it and following it up written in the offer, and are the distribution company's fees in the price?Approval is the distribution company's decision, and it is not automatic.
ScopeWhat is not included in the price?So that you compare totals for the same scope.
PaymentWhich stage is each payment tied to?So that payment keeps pace with the work.

An offer that answers these questions clearly deserves to be compared, whichever company wrote it. If you would like to know what our written offer holds:

Your personal offer

Your request's pathShort questions, A price on the screen, A written offer within one working day, The contract, Survey and installation

Your project file starts with your first answer.

Tell us a few details about your site; our team reviews them and prepares a preliminary study for you.

Start designing your plantTalk to an engineer