By the engineering team at pv.directLast updated: 20 November 2026
Capacity: kilowatt-peak.
Capacity is the combined rating of the panels under standard test conditions. A 100 kWp plant has panels rated at 100 kilowatts together. Capacity sets the size of the plant: the number of panels, the area and the inverter.
Production: kilowatt-hours.
Production is the energy the plant actually delivers over a period, in the same unit as your bill. It depends on the sun at your site, the tilt and orientation of the panels, shading, heat and dust.
From capacity to production.
We multiply the capacity by what one kilowatt-peak produces in a year. We calculate with 1,850 kWh per kWp a year, the figure our offer uses; the actual yield depends on the location and the roof. An example:
100 kWp1,850 kWh per kWp185,000 kWh a year
Production over the year.
The summer sun is stronger, so the plant produces more from May to September and less in winter. This chart spreads the example's production over the months with the same shares as our written offer.
- January10,383 kWh
- February11,327 kWh
- March14,158 kWh
- April16,046 kWh
- May17,934 kWh
- June18,878 kWh
- July19,821 kWh
- August19,821 kWh
- September17,934 kWh
- October16,046 kWh
- November12,270 kWh
- December10,382 kWh
And if production exceeds your use?
A grid-connected plant supplies your site first; what exceeds your use at any moment goes to the grid and is counted under net metering.